Sizing Guide
EXTRUDED ALUMINUM MODEL "EX" VENT
(4" deep channel frame style)
All sizes are width by height
All order size heights DO NOT INCLUDE top and bottom ribs.
To figure the size to order based on the existing rough opening OR the inside dimension of the duct the vent must fit inside:
ORDER SIZE WIDTH : Deduct a minimum of 1/4" from the opening size width.
ORDER SIZE HEIGHT : Deduct a minimum of 1/2" from the opening size height.
Note #1: You may want to deduct more from the opening to allow for a full mortar joint if the vents are being mortared in place. These figures above allow for a standard 1/8" caulk joint on alll four sides of the vent and take into consideration the ribs on the top and bottom of the vent.
Note #2: Brick vents are NOT undersized, therefore EX vents will finish 1/4" higher than the order size due to top and bottom mortar ribs. Width will finish true the order size.
EXTRUDED ALUMINUM MODEL "FL" VENT
(1-1/2" deep with 1" front flange frame style)
All sizes are width by height
All order size widths DO NOT INCLUDE screwheads on jamb sections.
Tip to Tip dimension of outside flange will be 2" wider and 2" higher than order size due to 1" front flange on all four sides of vent.
To figure the size to order based on the existing rough opening OR the inside dimension of the duct the vent must fit inside:
ORDER SIZE WIDTH : Deduct a minimum of 1/2" from the opening size width.
ORDER SIZE HEIGHT : Deduct a minimum of 1/4" from the opening size height.
Note #1: These figures above allow for a standard 1/8" caulk joint on all four sides of the vent and take into consideration the screwheads on the left and right hand interior sides of the vent.
Note #2: Brick vents are NOT undersized, therefore FL vents will finish 1/4" wider than the order size due to fastener heads on jamb sections. Height will finish true the order size.